Combo Meters
!
!

Cont usa only

SM802

!
SM802
SMART pH/EC/TDS COMBINED METER , RANGE: 0.00 – 14.00 pH, 0 – 4000 ppm, 0.00 – 6.00mS/cm, ACCURACY ±0.20 pH AND ± 2% FULL SCALE FOR EC AND TDS SUPPLIED WITH MA850 COMBINATION ELECTRODE, A9V BATTERY, A 20ml SACHET BUFFER SOLUTION OF pH7.01, 1500 ppm AND 1.413µS/cm

SM801

!
SM801
SMART pH/EC/TDS COMBINED METER, RANGE: 0.0 – 14.0 pH, 0 – 1990 ppm, 0 – 1990µS/cm, ACCURACY ±0.2 pH AND ± 2% FULL SCALE FOR EC AND TDS. SUPPLIED WITH MA850 COMBINATION ELECTRODE, A 9V BATTERY, A 20ml SACHET BUFFER SOLUTION OF pH7.01, 1382 ppm AND 1.413µS/cm.

MI151-US

!
MI151-US
pH / ORP / Temperature Bench meter, Range: -2.00 to 16.00 pH, +/- 699.9 mV, +/- 1999 mV, -20.0 to 120.0 C (-4.0 to 248.0F); accuracy of +/- 0.01 pH, +/-0.4C, automatic temperature compensation, automatic calibration in 1 or 2 points. Supplied with Refillable pH glass electrode MA917B/1, temperature proce MA831R, 12 VDC Adapter, electrode holder MA9315, sachet calibration solution (1 each of M10004, M10007, M10010, M100016) and instruction manual   NEW CONDITIONING SOLUTION AVAILABLE FOR ORP PROBE SEE MA9025 FOR DETAILS

MI150-US

!
MI150-US
pH / Temperature Bench meter, Range: -2.00 to 16.00 pH,-20.0 to 120.0 C (-4.0 to 248.0F); accuracy of +/- 0.01 pH, +/-0.4C, automatic temperature compensation, automatic calibration in 1 or 2 points. Supplied with Refillable pH glass electrode MA917B/1, temperature proce MA831R, 12 VDC Adapter, electrode holder MA9315, sachet calibration solution (1 each of M10004, M10007, M10010, M100016) and instruction manual

MI 190-US

!
MI 190-US
Ideal for testing Dissolved oxygen in the pharmaceutical and food Industry, as well as monitoring in water treatment plants. The user can choose to measure DO readings in mg/L or % saturation of O2.
This meter can be used for any type of water, as it allows measurements to compensate for temperature, altitude and salinity factors. The automatic logging interval can be set to perform analysis and store data into the memory.
All logged data can be downloaded to your PC through an RS232 or USB serial port. Memory can store up to 50 samples. Mi190 features an automatic calibration procedure, at 1 or 2 points (at 0 and 100% saturation). The polarographic probe supplied with the meter measures the current generated by the reaction of O2 with Ag.

MI 180-US

!
MI 180-US
MI 180-US
Mi180 measures 6 different parameters: pH, ORP, EC, TDS, percentage of NaCl and temperature in a variety of ranges.
pH calibration can be performed in 3 points selectable between 7 memorized buffers, to provide a very accurate calibration curve even when testing different samples, where verywide differences in pH can be found.
The auto-ranging feature for EC and TDS measurements automatically sets the resolution suitableto the tested sample. All measurements can be temperature compensated at 20 or 25C and the compensation coefficient is selectable by the user.
The automatic temperature compesnsation can also be disabled for measuring the actual conductivity value. The stability indicatoron the LCD ensures accuracy. Conducivity readings are performed with the 4-ring probe supplied with the meter.
The GLP feature allows users to store and recall data on system status. PC compatible through an RS232 port or USB.

MI 170-US

!
MI 170-US
COMBINED LOGGING WITH GLP EC/TDS/NaCl/°C BENCH METER; RANGE: EC 0.00 TO 29.99mS/cm; 30.0 TO 299.0 mS/cm; 3 to 29.99 mS/cm;  30.0 to 200.0 mS/cm; to 500.0 mS/cm WITHOUT CAT; TDS RANGE 0.00 to 14.99 mg/l (ppm); 150 to 1499 mg/l (ppme); 1.50 TO 14.99 g/l (ppt); 15.0 to 100 g/l (ppt); to 400.0 g/l;  NaCl RANGE 0 to 400%. °C RANGE: -9.9 to 120.0°C.  1 POINT CALIBRATION FOR EC WITH 6 MEMORIZED VALUES. NaCl WITH 1 POINT. SUPPLIED WITH MA813D/1  PROBE, ELECTRODE HOLDER MA9315, SOFTWARE Mi5200, RS232 CONNECTION WITH 2 METER CABLE, 12VDC ADAPTER AND CALIBRATION SOLUTIONS.

MI 160-US

!
MI 160-US
pH/ORP/ISE/ºC COMBINED LOGGING BENCH METER WITH AUTOMATIC CALIBRATION IN 1, 2 OR 3 POINTS WITH 7 SELECTABLE BUFFERS, RANGE -2.00 TO 16.00 pH / ± 699.9 mV / ±2000 mV/ 0.001 TO 19999 ppm / -20.0 to 120.0 ºC, ACCURACY OF ± 0.01 pH / ±1mV / 0.5% F.S / ±0.4ºC, AUTOMATIC TEMPERATURE COMPENSATION, GLP FUNCTION. SUPPLIED WITH A pH REFILLABLE ELECTRODE MA917B/1, TEMPERATURE PROBE MA831R, ELECTRODE HOLDER MA9315, RS232 CONNECTION WITH 2 METER CABLE, Mi5200 SOFTWARE, 12VDC ADAPTER AND CALIBRATION SOLUTIONS. NEW CONDITIONING SOLUTION AVAILABLE FOR ORP PROBE SEE MA9025 FOR DETAILS