Mi190-US DO / Temp Meter Lab Grade by Milwaukee Instruments

Manual

Milwaukee Mi190-US Included Accessories

1 - MA840/2 DO probe with 2 meter cable

1 - MA841 Spare membrane

1 - MA9071 Electrolyte solution

1 - MA9315 Electrode Holder

1 - Mi5200 Application Software

1 - MA9350 RS232 connection cable with 2 meters cable

1 - 12 VDC Adapter

1 - Instruction manual

Ideal for testing Dissolved oxygen in the pharmaceutical and food Industry, as well as monitoring in water treatment plants. The user can choose to measure DO readings in mg/L or % saturation of O2.
This meter can be used for any type of water, as it allows measurements to compensate for temperature, altitude and salinity factors. The Mi190-US automatic logging interval can be set to perform analysis and store data into the memory.
All logged data can be downloaded to your PC through an RS232 or USB serial port. Memory can store up to 50 samples. Mi190-US features an automatic calibration procedure, at 1 or 2 points (at 0 and 100% saturation). The polarographic probe supplied with the meter measures the current generated by the reaction of O2 with Ag.
 
Note: We only ship to the USA and Canada
The Milwaukee Mi190-US is ideal for testing Dissolved Oxygen in the pharmaceutical and food Industry, as well as monitoring in water treatment plants. The user can choose to measure D.O. readings inmg/L or % of saturation of O2. This meter can be used for any type of water, as it allows measurements to compensate for temperature, altitude and salinity factors. The automatic logging interval can be set to perform analysis and store data into the memory.

All logged data can be downloaded to your PC through an RS232 or USB serial port. Memory can store up to 50 samples. The Milwaukee Mi1 90 features an automatic calibration procedure, at1 or 2 points (at 0 and 100% of O2saturation). The polaro-graphic probe supplied with the meter (MA840/2) measures the current generated by the reaction of O2with Ag.

Milwaukee Mi-190 is supplied complete with MA840/2 DO probe with 2 m cable, 2 spare membranes, MA7041 electrolyte solution (30 mL), 12 VDC power adapter, probe holder and instruction manual.
 
Specifications of the MI 190 Meter
Range O2 0.00 to 45.00 mg/L (ppm)
% Saturation O2 0.0 to 300%
Temperature -5.0 to 55.0°C / 23.0 to 131.0°F
Resolution O2 0.01 mg/L (ppm)
% Saturation O2 0.1%
Temperature 0.1°C / 0.1°F
Accuracy O2 ±1.5 Full Scale
% Saturation O2 ±1.5 Full Scale
Temperature ±0.4°C / ±0.8°F
Logging 50 records, LOG on demand or auto-logging
DO Calibration automatic, 1 or 2 point at 0% (MA9070) and 100% (in air)
Temperature Compensation 0.0 to 50.0°C / 32.0 to 122.0°F
Altitude Compensation 0 to 4000 m; resolution 100 m
Salinity Compensation 0 to 40 g/L; resolution 1 g/L
DO Probe MA840/2 with DIN connector (included)
Temperature Probe Included in DO probe
Calibration 2 points (0.0°C and 50.0°C / 32.0 to 122.0°F)
Log on demand up to 50 records
PC interface RS232 / USB Opto-isolated
Environment 0 to 50°C / 32 to 122°F; max RH 100%
Power supply 12 VDC power adapter (included)
Dimensions Size 230 x 160 x 95 mm
Weight 0.9kg